Hot Water Sanitizable EDI Module
>
High Temperature Resistant EDI Module Chemical Free Regeneration With 90-95% Recovery

High Temperature Resistant EDI Module Chemical Free Regeneration With 90-95% Recovery

Merknaam: Aquacells
Modelnummer: EIMD-50HP
Detailinformatie
Plaats van herkomst:
China
Certificering:
FDA,EU,CE,RoHS ,REACH
Moduletype:
EDI (Elektrodeïonisatie)
Waterkwaliteitsoutput:
Type II of Type I ultrapuur water
Sollicitatie:
Farmaceutische, laboratorium- en halfgeleiderindustrieën
Maximale druk:
100 psi
Verbindingstype:
Standaard sanitaire uitrusting
Productnaam:
Heetwaterzuiverbare EDI-module
Nalevingsnormen:
FDA, USP, ISO 9001
Stroomsnelheid:
Varieert per model, doorgaans 1-10 GPM
Membraan materiaal:
Hoogwaardige ionenuitwisselingsmembranen
Elektriciteitsverbruik:
Laag, afhankelijk van het model
Garantieperiode:
1 jaarnorm
Ontsmettingsmethode:
Warm water
Bedrijfstemperatuur:
Tot 85°C
Module -afmetingen:
Varieert per model, meestal compact formaat
Ontsmettingsfrequentie:
Dagelijks of naar behoefte
Markeren:

High Temperature Resistant EDI Module

,

EDI Module 90-95% Recovery

Productomschrijving
Aquacells EIMD-50HP High-Temperature Resistant Chemical-Free Regeneration EDI Module with 90-95% Recovery
EIMD-HP Modules

The Aquacells EIMD-HP module is specifically engineered for hot water sanitization applications and is widely utilized in Pharmaceutical, biotechnology, and cosmetics industries. Constructed from high-temperature resistant materials to accommodate instantaneous heating and cooling requirements, this module delivers a constant flowrate of high-purity water without the need for chemical regeneration.

Feed Water Specifications
Parameter Specification
FCE (including CO2 and Silica) < 45 µS/cm
Temperature 5-45 ℃ (40-113 ℉)
Feed pressure 1.4-7 bar (20-100 psi)
Total Chlorine (as CI2) <0.05 ppm
Fe <0.01 ppm
Mn <0.01 ppm
S2- <0.01 ppm
pH 4-11
Total Hardness (as CaCO3) <1.0 ppm
Dissolved Organics (TOC as C) <0.5 ppm
Silica (SiO2) <1.0 ppm
Typical Module Performance
Parameter Performance
Typical Recovery 90-95%
Maximum Feed Pressure 7 bar (100 psi)
Maximum Feed Temperature 45 ℃ (113 ℉)
Sanitization Temperature at 30 psi (2.0 bar) 85 ℃ (185 ℉)
DC Voltage* 0-600 V
DC Amperage 0-10 A
Product Conductivity <0.1 µS/cm
Silica (SiO2) Removal 90-99% depending on feed water
*Voltage required depends on module size

The information provided in this brochure contains general descriptions or performance characteristics that may not always apply as described in actual use cases or may change due to further product development. An obligation to provide the respective characteristics shall only exist if expressly agreed upon in the terms of the contract.