Good price  online

products details

Home > Products >
High Purified EDI Module
>
High Purified EDI Module Ultrapure Water Module For Semiconductor Power Industries

High Purified EDI Module Ultrapure Water Module For Semiconductor Power Industries

Brand Name: Aquacells
Model Number: EIMD-DI
Detail Information
Place of Origin:
China
Certification:
FDA,EU,CE,RoHS,REACH
Maintenance Interval:
12-24 Months
Material:
High-grade Polymer And Ion Exchange Membranes
Operating Temperature:
5-45 °C
Product Name:
High Purified EDI Module
Current Density:
5-30 MA/cm²
Flow Rate:
Variable (e.g., 1-10 M³/h)
Purification Level:
High
Recovery Rate:
≥90%
Water Quality Output:
Resistivity ≥ 15 MΩ·cm
Application:
Water Purification
Module Dimensions:
Customizable Or Standard Sizes
Technology Type:
Electrodeionization (EDI)
Resin Type:
Mixed Bed Ion Exchange Resin
Operating Pressure:
0.1-0.6 MPa
Voltage:
12-48 V DC
Highlight:

High Purified EDI Module

,

Ultrapure Water EDI Module

,

Semiconductor Ultrapure Water Module

Product Description
EIMD - UP Ultrapure Water Module With >16MΩ*Cm Resistivity 90-99% Silica Removal And 90-95% Recovery For Semiconductor And Power Industries

Aquacells EIMD-UP module are designed for ultrapure water applications,with a primary focus on meeting the high-standard water quality requirements of the semiconductor and pharmaceutical industries.

Feed Water Specifications
Parameter Specification
FCE (including CO2 and Silica) < 45 µS/cm
Temperature 5-45 ℃ (40-113 ℉)
Feed pressure 1.4-7 bar (20-100 psi)
Total Chlorine (as CI2) <0.05 ppm
Fe <0.01 ppm
Mn <0.01 ppm
S2- <0.01 ppm
pH 4-11
Total Hardness (as CaCO3) <1.0ppm
Dissolved Organics (TOC as C) <0.5ppm
Silica (SiO2) <1.0ppm
Typical Module Performance
Parameter Specification
Typical Recovery 90-95%
Maximum Feed Pressure 7 bar (100 psi)
Maximum Feed Temperature  45 ℃ (113 ℉)
DC Voltage* 0-300 V
DC Amperage 0-6 A
Product Resistivity >16 MΩ·cm
Silica (SiO2) Removal 90-99% depending on feed water

*Voltage required depends on module size

The information provided in this brochure contains general descriptions or performance characteristics that may not always apply as described in actual use cases or may change due to further product development. An obligation to provide the respective characteristics shall only exist if expressly agreed upon in the terms of the contract.